Software for clinics & diagnostic labs. From ₹399/mo, 10-day free trial. See plans →

Serum Bilirubin report format

A serum bilirubin report format with total, direct and indirect bilirubin and reference ranges.

Sample Serum Method Diazonium (Jendrassik-Grof)

Report layout used at Sobhana Diagnostics, signed by Dr. V. Aruna Sree, MBBS, DCP · Consultant Pathologist

Serum Bilirubin report format sample, branded with HealthFlow, showing results, units and reference ranges
Serum Bilirubin report format on a lab letterhead. Specimen: Serum. Method: Diazonium (Jendrassik-Grof). Each result is shown against its unit and reference range, with out-of-range values flagged.

Sample format. "Your Lab Name" is a placeholder. On HealthFlow every report carries your lab's own logo, letterhead and colours, and the QR opens the authentic signed copy through a logged verification gateway.

What this Serum Bilirubin format includes

Every line carries the result, its unit and the reference range, with out-of-range values flagged. The values below are sample values, shown so you can see the layout.

TestResult Unit Reference range
Total Bilirubin 2.1 ↑ mg/dL 0.3 - 1.2
Direct (Conjugated) Bilirubin 0.6 ↑ mg/dL 0.0 - 0.2
Indirect (Unconjugated) Bilirubin 1.5 ↑ mg/dL 0.2 - 0.8

How a Serum Bilirubin report is read

  • Serum bilirubin should be interpreted together with the liver enzymes and the clinical picture.
  • A predominant rise in unconjugated (indirect) bilirubin suggests haemolysis or Gilbert's syndrome, while a conjugated (direct) rise suggests hepatocellular or obstructive causes.
  • Reference ranges vary with age (notably in neonates) and method.

What commonly goes wrong with a Serum Bilirubin

The practical errors that actually cause repeat samples and misread results, mostly at collection and at the point the result is read.

  • Indirect bilirubin is calculated as total minus direct, never measured. A report where direct exceeds total is arithmetically impossible and points to an analytical or transcription error, so the panel is repeated.
  • Bilirubin is light sensitive. Samples left uncovered on the bench lose bilirubin over hours and read falsely low, which matters most in exactly the cases where the number decides the next step.
  • In a newborn the value only means something against the baby's age in hours. A total bilirubin issued without the time of birth and the time of collection cannot be plotted by the treating doctor.
  • Haemolysis and lipaemia both interfere with the diazo reaction, so a grossly haemolysed or milky sample should be rejected rather than reported with a disclaimer.
What does a Serum Bilirubin report format include?

A serum bilirubin report format with total, direct and indirect bilirubin and reference ranges. Each line shows the result, its unit and the reference range, with out-of-range values flagged, followed by clinical notes on how the test is interpreted.

Can this Serum Bilirubin format carry my lab's brand?

Yes. On HealthFlow the report is white-label: your lab's logo, letterhead, address and colours replace the "Your Lab Name" placeholder, and it can be printed or delivered on WhatsApp from your own number.

WhatsApp us Call